UV Disinfection for Wastewater Treatment and Water Reuse: Design Guide
How should UV disinfection systems be designed for wastewater treatment and water reuse? This engineering guide explains the key parameters influencing UV system selection, including design flow, UV transmittance (UVT), suspended solids, UV dose, validation and hydraulic conditions. Explore the differences between open-channel and closed-vessel UV reactors, along with monitoring, automatic cleaning, maintenance and lifecycle costs. Learn how Longking EnTech Europe's NLQ and NLC technologies can be evaluated for project-specific requirements.
Ozone in Drinking Water Treatment: Applications and Design Criteria
Ensuring safe and high-quality drinking water is becoming increasingly complex. Water utilities must respond not only to conventional microbiological risks, but also to seasonal variations in raw water, algal blooms, natural organic matter, taste and odor events, metals, micropollutants and stricter requirements regarding disinfection by-products.
Longking EnTech Europe to Supply Open Channel UV System for Villafranca de los Barros WWTP
Longking EnTech Europe will supply a Longking NLQ-32 H open channel UV disinfection system for the Villafranca de los Barros WWTP in Spain, enabling chemical-free treated wastewater effluent disinfection.
Longking at IFAT Munich 2026: Ozone for Micropollutant Removal
Longking EnTech Europe highlighted ozone-based micropollutant removal and quaternary wastewater treatment at IFAT Munich 2026. This article explores the revised EU Urban Wastewater Treatment Directive, the role of ozonation in advanced treatment, oxidation by-product management and Longking's integrated engineering approach for municipal and industrial wastewater applications.
Open-Channel UV Retrofit: How to Upgrade Existing Disinfection Systems
Modernizing an existing open-channel UV disinfection system does not always require rebuilding the plant. Discover how Longking EnTech Europe evaluates UV retrofit projects, including hydraulic compatibility, UV dose recalculation, selection of NLQ-H, NLQ-V and NLQ-HPV systems, automatic cleaning, PLC/SCADA integration and lifecycle costs.
Real Ozonation Efficiency: 5 Factors That Determine Ozone System Performance
Real ozonation efficiency depends on more than ozone generator capacity. This article explains five key factors that determine system performance: feed-gas selection, ozone transfer efficiency, contact chamber hydraulics and CFD, cooling and automation, and long-term maintenance and monitoring.
Open-Channel UV in Wastewater: How to Define UV Dose, UVT and the Hydraulic Design Window
In open-channel wastewater UV systems, dose alone is not a design basis. Reliable disinfection depends on the real operating window formed by UVT, suspended solids, flow and channel hydraulics.
Longking EnTech Europe at IFAT Munich 2026: Ozone & UV Water Treatment
Longking EnTech Europe announced its participation at IFAT Munich 2026, highlighting two water treatment technologies: NLO-LITE compact ozone generators and NLQ-HPV high-power vertical UV disinfection systems. The announcement focused on efficient system integration, hydraulic design, automation and operational reliability for municipal and industrial water treatment applications.
Ozonation and Ozone-Based AOP for Endocrine Disruptor Abatement
A technical design guide to ozonation and ozone-based AOP for EDC/micropollutant control. Covers matrix drivers, dose and contacting logic, off-gas safety, BAC/GAC polishing, verification/commissioning, and what to specify for ozone generators—incl. Longking NLO integration.
Compact 1 kg/h ozone generator strengthens drinking water pre-ozonation in Sotillo de la Adrada (Spain)
Sotillo de la Adrada upgrades drinking water pre-ozonation with a compact 1 kg/h NLO LITE ozone generator fed by PSA oxygen, ceramic diffusers and full safety systems.
Wastewater UV Disinfection: Why a Multi-Barrier Approach Beats “UV Alone”
UV disinfection in wastewater is rarely limited by lamp power alone. Stable performance depends on UVT variability, particle shielding (TSS/turbidity), hydraulics, and fouling control. This article explains why a multi-barrier approach (polishing/filtration + UV) delivers consistent compliance—and how Longking’s NLQ-H and NLQ-HPV open-channel systems are engineered for predictable dose under real effluent conditions.
Endocrine Disruptors in Water
Europe is moving endocrine disruptors (EDCs) from “emerging concern” to structured monitoring and upgrade planning in both drinking water and wastewater. This technical insight explains what utilities should specify now—indicators, sampling points, verification—and why ozonation + polishing (BAC/GAC) is often the most defensible barrier train, enabled by stable ozone generation with Longking NLO systems.
Season’s Greetings & 2025 Business Update — Longking EnTech Europe
A year of consolidation and positive integration: Longking EnTech Europe strengthens its ozone and UV platform for the European water market and sets clear priorities for 2026.
Longking EnTech Europe and MITINFRA commissioned a 160 kg/h ozone system at El Ahogado WWP (Mexico) to support NOM-001-SEMARNAT-2021 compliance.
Longking EnTech Europe commissioned a 160 kg/h ozone treatment system at El Ahogado Wastewater Plant (Mexico) with MITINFRA. Designed to support NOM-001-SEMARNAT-2021, the integrated package (generation, diffusion, automation, off-gas destruction and cooling) strengthens disinfection, color removal and toxicity reduction
Longking Launches NLQ-HPV 800 W Open-Channel UV Disinfection System
Longking EnTech Europe introduces the NLQ-HPV Series, a high-power vertical open-channel UV disinfection system for municipal wastewater treatment and water reuse. Featuring 800 W low-pressure amalgam lamps, 16-lamp modules, automatic mechanical cleaning, UV intensity monitoring and intelligent power regulation, NLQ-HPV provides a modular platform for large wastewater treatment plants, new installations and technically feasible retrofit projects.
High-Efficiency Ozone System Commissioned at the Venta Alta Drinking Water Plant in Bilbao
Longking EnTech Europe commissioned a 40 kg/h ozone system at the Venta Alta Drinking Water Plant in Bilbao, Spain. The installation uses two NLO20 oxygen-fed ozone generators integrated into pre-ozonation and intermediate ozonation stages, with plant automation and SCADA integration
The Role of Ozone in Multi-Barrier Processes for Drinking Water
Ozone is a key technology in modern multi-barrier drinking water treatment, enhancing disinfection, oxidation, and downstream performance. Learn how ozone strengthens safety, efficiency and regulatory compliance in potable water processes.
Choosing the Right Feed Gas for Ozone Systems: Dry Air, PSA or LOX?
Choosing between LOX, PSA and dry air is a key engineering decision in an ozone system. This guide compares the three feed-gas alternatives and explains their impact on ozone concentration, energy consumption, equipment, oxygen logistics, redundancy and lifecycle cost.
Ozone Transfer in Water Treatment: Why Contact Chamber Design Matters
Ozone treatment performance depends on more than ozone production. This technical article explains how gas concentration, diffuser design, water depth, T10, contact chamber hydraulics, CFD and water chemistry influence ozone transfer and overall ozonation performance.
Longking NLQ Open-Channel UV Systems: Horizontal vs Vertical Configurations
Discover the differences between Longking's NLQ-H, NLQ-V and NLQ-HPV open-channel UV disinfection systems. This technical guide compares horizontal and vertical module configurations, 320 W and 800 W amalgam UV lamps, automatic cleaning, power regulation and SCADA integration. Learn how wastewater quality, treatment capacity, hydraulic conditions and maintenance requirements influence UV system selection for municipal wastewater treatment, water reuse and retrofit projects.