Longking EnTech Europe at IFAT Munich 2026
IFAT Munich 2026, held from 4 to 7 May 2026 in Munich, Germany, brought together the international environmental technology sector, including companies specializing in water treatment, wastewater management and resource recovery.
Ahead of the exhibition, Longking EnTech Europe announced its participation in Hall A3, Stand 537, with a focus on ozone generation and ultraviolet (UV) disinfection technologies for municipal and industrial water treatment applications.
The company's planned showcase highlighted two technology platforms: the NLO-LITE compact ozone generator series and the NLQ-HPV high-power vertical UV disinfection systems.
The participation announcement focused on practical engineering challenges, including system efficiency, compact equipment design, integration into existing treatment plants, process automation and long-term operational reliability.
Why did Longking highlight ozone and UV at IFAT Munich 2026?
Municipal and industrial water treatment plants face increasing demands for reliable treatment performance, energy efficiency and operational flexibility. Variations in water flow, water quality, UV transmittance (UVT) and oxidant demand make proper technology selection and process engineering essential.
Ozone and ultraviolet (UV) technologies address different treatment objectives and can be applied independently or as complementary processes within a water treatment plant.
Ozone is used for oxidation, treatment of selected contaminants and disinfection applications, depending on process requirements. UV is widely used for microbial disinfection without the addition of chemical disinfectants.
For both technologies, reliable performance depends not only on equipment capacity but also on correct sizing, hydraulic integration, instrumentation, automation and maintenance.
Engineering challenges highlighted for IFAT Munich 2026
Longking EnTech Europe's participation announcement focused on three practical engineering questions:
Compact ozonation: How can ozone generation, gas preparation, cooling, ozone transfer and safety systems be integrated into compact installations without compromising operational reliability?
High-flow UV disinfection: How can open-channel UV systems be integrated into new or existing treatment plants while considering UVT, hydraulic conditions, required disinfection performance and available installation space?
Automation and operational control: How can monitoring, power regulation, process control and plant integration help maintain reliable performance under changing operating conditions?
These considerations framed the presentation of Longking's NLO-LITE compact ozone generators and NLQ-HPV high-power vertical UV disinfection systems in its IFAT Munich 2026 participation announcement.
Ozone and UV technologies highlighted for IFAT Munich 2026
Longking EnTech Europe's participation announcement highlighted two technology platforms developed for different water treatment requirements: NLO-LITE compact ozone generators and NLQ-HPV high-power vertical UV disinfection systems.
Both technologies reflect the importance of combining equipment performance with practical engineering, system integration, automation and operational reliability.
1. NLO-LITE: compact ozone generation for water treatment
The Longking NLO-LITE Series is a compact ozone generation platform designed for municipal and industrial water treatment applications requiring relatively low ozone production capacities, reduced installation space and flexible system integration.
The technology can be incorporated into water reuse installations, industrial process water treatment, aquaculture systems, pilot plants and containerized ozone solutions.
Main technical characteristics of NLO-LITE
Ozone production: 0.5–1.5 kg O₃/h, depending on the selected model and configuration.
Feed gas: Oxygen supplied from PSA or LOX, or properly treated dry air.
Ozone concentration: Up to 296 g O₃/Nm³ with oxygen feed, depending on operating conditions.
Specific energy consumption: ≤8 kWh/kg O₃ with oxygen feed, depending on the model and operating conditions.
Cooling system: Closed-loop water cooling.
Materials in contact with ozone: AISI 316L and PTFE.
Automation: Integrated PLC-based control with optional HMI.
Communications: Ethernet connectivity for integration with external monitoring and plant-control systems.
The distinction between feed gas and cooling technology is important. NLO-LITE can operate with either oxygen or treated dry air, but the generator uses water cooling in both cases.
Where can NLO-LITE be applied?
NLO-LITE is particularly relevant for projects requiring compact ozone generation combined with flexible integration into a complete treatment process.
Potential applications include:
Municipal and industrial water reuse.
Industrial process water treatment.
Wastewater oxidation and advanced treatment.
Recirculating aquaculture systems (RAS).
Pilot and demonstration installations.
Compact skids and containerized ozone systems.
The appropriate equipment configuration depends on ozone demand, water quality, feed-gas availability, contact-system design, utilities and the required operating conditions.
For detailed information, visit our NLO-LITE compact ozone generators product page.
2. NLQ-HPV: high-power vertical UV disinfection for open-channel applications
The Longking NLQ-HPV Series is designed for high-flow ultraviolet disinfection in municipal and industrial water treatment plants, combining high-power amalgam UV lamps with a vertical open-channel configuration.
The system is particularly relevant for large wastewater treatment plants, water reuse installations and projects where hydraulic integration, available channel space and operational reliability are important design considerations.
Main technical characteristics of NLQ-HPV
UV lamp technology: High-power, low-pressure amalgam UV-C lamps rated at 800 W electrical power per lamp.
Module configuration: Vertical UV modules with 16 lamps per module in the reference configuration.
Installation: Open-channel arrangement designed to accommodate project-specific hydraulic conditions.
Materials: AISI 316L stainless steel for submerged components, with AISI 304 typically used for components above water level, subject to project requirements.
Cleaning system: Automatic mechanical cleaning of quartz sleeves using pneumatically actuated wipers. A compressed-air supply is required.
Instrumentation: UV intensity sensors and ultrasonic water-level measurement.
Automation: PLC-based control with HMI and interfaces for integration with plant automation or SCADA systems.
Power regulation: Lamp power adjustment according to the configured disinfection control strategy and available process signals.
Maintenance: Modular arrangement intended to facilitate routine inspection, cleaning and lamp maintenance.
Why are hydraulic design and UV dose important?
High lamp power alone does not guarantee the required disinfection performance.
Correct UV system design depends on several interacting parameters:
Maximum, nominal and minimum water flow.
UV transmittance (UVT) at 254 nm.
Suspended solids concentration.
Required disinfection performance and applicable validation criteria.
Channel dimensions and water-level control.
Flow distribution through the UV modules.
Lamp ageing and fouling assumptions.
For this reason, the number of lamps and modules must be selected according to the specific treatment conditions rather than from nominal flow capacity alone.
UV intensity monitoring, combined with the appropriate operating parameters and validated design methodology where applicable, supports disinfection control. UV dose should not be presented as a directly measured parameter solely from the intensity sensor.
Where can NLQ-HPV be applied?
The NLQ-HPV platform is particularly suited to:
Municipal wastewater disinfection.
Tertiary treatment and water reuse.
High-flow industrial wastewater applications.
New open-channel UV installations.
Modernization and retrofitting of existing UV channels, subject to hydraulic feasibility.
By combining 800 W UV lamps, vertical modules, automatic cleaning and PLC-based control, the NLQ-HPV Series provides an engineering platform for projects requiring high treatment capacity within defined installation constraints.
For further technical information, visit our NLQ-HPV high-power vertical UV disinfection systems product page.
Engineering support for ozone and UV water treatment projects
Longking EnTech Europe's participation announcement for IFAT Munich 2026 reflected the company's focus on practical engineering solutions for municipal and industrial water treatment.
Whether a project involves a new installation or modernization of an existing treatment plant, successful ozone and UV implementation requires more than selecting equipment from a catalogue.
For an initial technical assessment, the most useful information includes:
For ozone systems: Water flow, treatment objectives, estimated ozone demand, feed-gas availability, contact-system configuration and operating requirements.
For UV disinfection: Design flow, UV transmittance (UVT), suspended solids, required disinfection performance, channel dimensions and installation constraints.
For both technologies: Available utilities, automation requirements, redundancy philosophy, maintenance accessibility and project-specific limitations.
Longking EnTech Europe supports customers and engineering partners in evaluating these requirements and developing suitable ozone generation and UV disinfection solutions.
The NLO-LITE and NLQ-HPV technologies highlighted in the IFAT Munich 2026 announcement represent two examples of Longking's broader water treatment portfolio.
If you are evaluating an ozone or UV project, our engineering and commercial teams can help review the requirements and identify an appropriate technical approach.

